Cdn INTP626X - ProAccurate® Infrared/Thermocouple Prob User Manual Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 4
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
5.Replacethebatterycover,
bottomedgerst.
Important:Thewaterresistantfeature
requiresmaintainingatighttforthe
batterycoverandtherubbercap.
6.Fastenthescrewonthebattery
coverbyturningitclockwise.
7. Replacetherubbercapoverthe
screwbypushingitdownsecurely.
Operating Instructions
Mode Selection:MINØMAXØLOCKØ°C/°FØEMIS
A. Temperature Scale
ToselecttemperaturereadinginFahrenheitor
Celsius:
1.PresstheSCANbuttontoturnthethermometer
on.
2.PresstheMODEbuttonfourtimes.The°For
°Csymbolashesonthedisplay.
3.PresstheSCANbuttontochangethescale.
B. Infrared Thermometer
InfraredisthedefaultmodeoftheINTP626X.
Note:TheINTP626Xisintendedforfoodserviceuse—do
notuseforsafetyrelatedapplications.
1. Infrared Scanning
a.Distance:Spot = 2.5:1
Forexample,ifthe
surfaceareabeing
measuredis10"in
diameter,thenthe
thermometermustbewithin25"ofthetarget
foranaccuratereading.
b.Aimtheinfraredlensatthetargetandpress
theSCANbuttontodisplaythesurface
temperature.The white light automatically
turns on to illuminate the target.
c. Measurementcontinuesaslongasthe
SCANbuttonispressed.Thenewestreading
updatesthedisplay.
d.WhentheSCANbuttonisreleased,HOLD
appearsonthedisplayandthelastreading
remainsvisiblefor15secondsbeforetheunit
automaticallypowersoff.
2. Minimum Mode
a.PresstheSCANbuttontoturnthe
thermometeron.
b.PresstheMODEbuttononce.MIN asheson
thedisplay.
c. PressandholdtheSCANbuttontoconrm
theMinimumModeanddisplaythelowest
temperatureamongmultipletargets.
3. Maximum Mode
a.PresstheSCANbuttontoturnthe
thermometeron.
b.PresstheMODEbuttontwice.MAX ashes
onthedisplay.
c. PressandholdtheSCANbuttontoconrm
theMaximumModeanddisplaythehighest
temperatureamongmultipletargets.
4. Lock Mode
Thisisparticularlyusefulforcontinuous
temperaturemonitoring.
a.PresstheSCANbuttontoturnthe
thermometeron.
b.PresstheMODEbuttonthreetimes.LOCK
ashesonthedisplay.
c. PresstheSCANbuttontoconrmthe
LockMode.Thethermometercontinuously
displaysthetemperatureforupto60minutes
oruntiltheSCANbuttonispressedagain.
5. Emissivity
Everythinggivesoffacertainamountof
radiation.Emissivityisthemeasureofthis
thermalradiation.Theinfraredthermometeris
suppliedwithadefaultemissivityof0.95,which
standardformostuses.Theemissivityofthe
thermometercanbechangedfrom0.05(5E)to
1(100E).Only experienced personnel should
attempt to make changes.Forinformation
relatingtotheemissivityofspecicmaterials,
pleasecontactCDN.
a.PresstheSCANbuttontoturnthe
thermometeron.
b.PresstheMODEbuttonvetimestoenter
EmissivityMode.95E ashesonthedisplay.
c. PresstheSCANbuttontoadjustthe
emissivityvaluein0.01(1E)increments.
d.PresstheMODEbuttonagaintoexit
EmissivityMode.
Note:Non-contactinfraredthermometersarenot
recommendedforuseinmeasuringthetemperatureof
shinyorpolishedmetals.
6. Error Messages
TheINTP626Xincorporatesvisualdiagnostic
messagesasfollows:
a.HI orLO isdisplayedwhenthetemperature
beingmeasuredisoutsidetheinfraredrange
oftheinstrument.
1.)HI indicatesthatthetemperatureis
higherthan+482°F/+250°C.
2.)LO indicatesthatthetemperatureis
lowerthan-67°F/–55°C.
b.Allowaminimum30minutesforthe
thermometertostabilizetotheworking/
roomtemperature.
1.)ER2 isdisplayedwhenthe
Distance:Spot(FOV)=2.5:1
Emissivity=0.1~1,Step.01
WaveLength=8µm-14µm
5
6
7
Page view 1
1 2 3 4

Comments to this Manuals

No comments